|


8100 General Purpose Receiver |
Specifications (用英语) |
|
General data
|
|
Screening
|
60 dB
|
|
Spurious Emissions
|
1 nW maximum
|
|
Battery State Indicator
|
Visual on display plus audible warning
|
|
Battery Life
|
8 hours, dependent upon volume level
|
|
Charging Time
|
16 hours
|
|
Weight
|
6 kg (including case and batteries)
|
|
Dimensions
|
330 x 115 x 240 mm (including case)
|
|
Operating Temperature Range
|
0 - 40°C
|
|
Lock
|
Front Panel control lock
|
|
Frequency
|
|
Range
|
100 kHz - 26 MHz (reduced specification) 26 MHz - 1000 MHz
|
|
Accuracy
|
± 2.5 kHz
|
|
Tuning Increments
|
0.5, 1, 5, 6.25, 10, 12.5, 20, 25, 50 kHz steps
|
|
Frequency Offsets
|
5, 6.25, 10, 12.5, 25 kHz steps
|
|
Frequency Scanning
|
Between user set limits
|
|
Lockout Frequencies
|
Up to 100
|
|
Hold Time
|
Adjustable 0-9.9 seconds
|
|
Dwell Time
|
Adjustable 0-9.9 seconds
|
|
Resume Time
|
Adjustable 0-9.9 seconds and off
|
|
Amplitude
|
|
Measuring Range
|
-10 dBµV to + 110 dBµV : 26 - 1000 MHz
|
|
7.5 kHz bandwidth
|
+5 dBµV to + 110 dBµV : 100 kHz - 1 MHz
|
|
Average detection
|
0 dBµV to + 110 dBµV : 1 - 26 MHz
|
|
Level Readout Resolution
|
0.1 dB
|
|
Displayed Range
|
84 dB bargraph display
|
|
Level Accuracy
|
± 1.5 dB max, typically ± 0.5 dB : 26 - 1000 MHz
|
|
Hold Time
|
Adjustable 0-9.9 seconds
|
|
7.5 kHz bandwidth
|
± 3 dB : 100 kHz - 26 MHz
|
|
Level Detection Time Constants
|
Average 5 ms, 0.1 s, 1 s.Peak hold time 1 s
|
|
Measuring Units
|
dBµV, µV, dB relative, dB µV/metre, dBm
|
|
Selectivity
|
|
IF Frequencies
|
301.5 MHz, 21.4 MHz, 455 kHz
|
|
Bandwidth 3 dB
|
+5 dBµV to + 110 dBµV : 100 kHz - 1 MHz
|
|
8101
|
7.5, 15 and 120 kHz
|
|
8102
|
7.5, 15, 20 and 120 kHz
|
|
8103
|
7.5, 15, 25, 120 kHz
|
|
Adjacent Channel
|
Greater than 45 dB. (12.5 kHz channel spacing)
|
|
Rejection
|
Greater than 50 dB. (25.0 kHz channel spacing)
|
|
Image Rejection
|
50 dB minimum. Typically 70 dB (level required to produce an indication of 0 dBµV).
|
|
IF Rejection
|
70 dB minimum. (230-400 MHz, 50dB minimum) Typically 80 dB
(level required to produce an indication of 0 dBµV).
|
|
Spurious Response Rejection
|
Typically 50 dB
(level required to produce an indication of 0 dBµV)
|
|
Blocking
|
75 dBµV minimum
(1 dB level change, 0 dBµV signal, 2 MHz away)
|
|
Intermodulation
|
55 dB minimum (1 mV p.d. input, 50 kHz separation)
|
|
Input
|
|
RF Input Impedance
|
Nominally 50 Ω
|
|
Antenna Input
|
“N” type connector
|
|
Input VSWR
|
Less than 2: 1 without RF attenuation
Less than 1.4 : 1 with RF attenuation selected
|
|
RF Attenuation
|
20 dB
|
|
IF Attenuation
|
10, 20 or 30 dB
|
|
Max. Safe Level
|
3.5 V rms (250 mW) +23 dBm at max. Sensitivity
|
|
Overload Display
|
Visual and Audible
|
|
Audio
|
|
Audio Demodulation
|
AM, FM
|
|
Typical Signal-to-Noise Ratio (S+N/N, audio filter selected):
AM: Typically 10 dB (6 dB < 26 MHz) for 0 dBµV signal, 30 % modulation, 1 kHz tone, audio filter in.
FM: Typically 20 dB (14 dB < 26 MHz) for 0 dBµV signal, 1.5 kHz peak deviation, 1 kHz tone, audio filter in.
|
|
Audio Filter
|
300 Hz ±50Hz - 1 dB to 2.4 kHz ± 300 Hz - 3 dB (switchable).
|
|
600 Ω Line Output
|
Adjustable from Front Panel. Nominally 0 dBm (600 Ω)
|
|
Audio Output
|
1.0 W to 3.0 W (dependent upon battery state)
|
|
Modulation Measurement: (with 400 Hz Modulation)
|
|
AM
|
Range
|
0 to 90% (0 to 126% indicated)
|
|
Accuracy
|
± 5%
|
|
FM (7.5 kHz bandwidth)
|
Range
|
0 - 3.7 kHz peak deviation
(0 - 4.2 kHz indicated)
|
|
Accuracy
|
± 500 Hz
|
|
FM (15 kHz bandwidth)
|
Range
|
0 - 7.5 kHz peak deviation
(0 - 8.4 kHz indicated)
|
|
Accuracy
|
± 500 Hz
|
|
FM (20 kHz bandwidth)
|
Range
|
0 - 10 kHz peak deviation
(0 - 16.8 kHz indicated)
|
|
Accuracy
|
± 500 Hz
|
|
FM (25 kHz bandwidth)
|
Range
|
0 - 12.5 kHz peak deviation
(0 - 16.8 kHz indicated)
|
|
Accuracy
|
± 500 Hz
|
|
FM
(120 kHz bandwidth)
|
Range
|
0 - 60 kHz peak deviation
(0 - 84 kHz indicated)
|
|
Accuracy
|
± 5 kHz
|
|
Memory
|
|
Memory
|
40 memories of receiver status
|
|
Memory Scanning
|
All 40 memories or any selected number
|
|
Hold Time
|
Adjustable 0 - 9.9 seconds
|
|
Dwell Time
|
Adjustable 0 - 9.9 seconds
|
|
Resume Time
|
Adjustable 0 - 9.9 seconds and OFF
|
|
Memory Backup
|
10 years
|
|
Auxiliary Outputs
|
|
Serial Data
|
RS 232 control of all functions
|
|
Loudspeaker
|
1.0 W to 3.0 W into 8 Ω (dependent upon battery state)
|
|
Low Level Audio (Line Out)
|
Variable using Front Panel control but nominally 0 dBm (600 Ω)
|
|
Signal Level
|
Full scale on bargraph 6 V
Noise level approx 2V (typical)
|
|
2 Squelch Operated Changeover Relay Contacts
|
Maximum 0.5 A, 28 V dc contacts electrically isolated from receiver.
|
|
Demodulation
|
Unfiltered demodulator output
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2011年2月16日 用于2305 Stabilock的新固件添加了用于基站测试的“自动运行”功能,用于BS远程控制的新选项
> 更多信息
|
|
|
|
|
2011年2月2日 Aeroflex推出用于2201 ProLock电话测试仪的新选项,以提高WCDMA测试速度,向GSM和HSDPA测试添加了网络交换测试
> 更多信息
|
|
|
|
|
2010 年 4 月 20 日 新型 TETRA 测试仪支持基站和无线终端的维修
> 更多信息
|
|
|
|
|
|
|
|
|
8010 Hindsite RF Propagation Test Software
> 更多信息
|
|
|
|
|
|
 |
|
 |
|
 |
|
 |
|
|