Specifications (用英语)

General data

Display (TFT)

Size

6.5''

Brightness

300 cd

Resolution

640 x 480, 256 Colours

Measurement result points

2 x 501
(Two independent traces are available,
min. hold, max. hold at the same time)

Power supply

DC voltage, external

11 to 15 V / max. 28 W

Changeable Internal battery

Li-Ion

Operating time (battery fully charged, full brightness)

min. 2.1 h

Memory

Type

Flash Disk

Capacity (set-ups and traces)

257

Dimensions (W x H x D)

355 x 190 x 85 [mm]

Weight

With battery

3.0 kg (6.6 lbs)

Power supply only

0.32 kg (0.7 lbs)

Environmental conditions (unless otherwise specified)

MIL-PRF28800F class 2

Operating temperature

0 to +45°C

Rel. humidity (non-condensing)

80%

Storage temperature

–10 to + 50°C

Connectors

RF in

Connector type N (female), impedance 50 ohm

Serial interface

For software updates and remote control
Speed 57.6 kbit/s

LAN (TCP/IP)

For software updates and remote control
Speed 10 Mbit/s

Standard deliveries

9101 Handheld Spectrum Analyzer incl. 9100 Data Exchange Software, AC power supply (90 to 240 V/50 to 60 Hz), Cross-link Ethernet cable, user's guide on CD and getting started manual

Frequency

Frequency range

Measurement range

100 kHz to 4 GHz

Frequency accuracy

2 ppm

Resolution

1 kHz

Sweep time

Span > 100 kHz

1 ms to 250 s

Span = 0 Hz

1 ms to 250 s

Resolution bandwidth (RBW)

RBW (–3 dB) range 100 Hz to 1 MHz (RBW selection manual or automatic)

Video bandwidth (VBW)

VBW range (–3 dB) 10 Hz to 1 MHz (VBW selection manual or automatic)

SSB noise

< –83 dBc/Hz (f = 2 GHz, Δf = 100 kHz, RBW = 10 kHz, VBW = 1 kHz)

Amplitude

Measurement range

Averaged noise floor to 20 dBm

Display units

dBm, dBµV, dBmV, dBV, dB, V, mV, µV, mW, µW

Displayed average noise level (DANL) (RBW = 100 Hz, attenuation = 0 dB)

10 to 1000 MHz

< –127 dBm,
typ.–130 dBm

1000 to 4000 MHz

< –130 dBm,
typ.–125 dBm

Input attenuation

Setting range

(0) 10 to 50 dB

Attenuation steps

10 dB

Dynamic range

Range

> 65 dB

Max. measurable input level (attenuation = 50 dB)

20 dBm

Min. measurable input level

–130 dBm

Level accuracy

10 to 3600 MHz

±1 dB

VSWR RF input

10 to 4000 MHz, input attenuation = 10dB

< 1.6

Spurious response

Image rejection (f = 1 GHz)

> 80 dB

LO breakthrough (attenuation = 10 dB)

< –72 dBm

Spurious level (attenuation = 0 dB)

< –90 dBm

Intermodulation-free range
(input level –30 dBm, f1 = 990 MHz, f2 = 992 MHz)

> 63 dB

Frequency counter

Resolution

1 Hz, 10 Hz, 100 Hz

Min. required input level

-90 dBm

Functions

Detector & sweep

Detector types

pos./neg. peak, pos. peak, neg. peak, sample, RMS (optional)

Sweep processing

actual, average, max. hold, min. hold

Trace

Max. displayed traces

2

Trace points

2 x 501
(Two independent traces are available, min. hold, max. hold at the same time)

Trace functions

A+B → A, A–B → A,
copy a>b, copy b>a

Marker

Max. markers

6

Delta markers

5

Marker functions

max. peak, next peak

Transfer functions

M → centre frequency, M → ref. level, M → f step

Limit check

Limit functions

upper, lower, upper and lower

Power measurement

Measurement functions

Channel Power, ACPR, OBW

Default systems

GSM, WCDMA, DECT, WLAN

Demodulation

AM/FM

on marker/permanent/on multi marker