主页 请联系我们 网点地址 首页 Sales Partner World
产品系列 方法处理 技术进步 培训及服务 公司介绍 新闻发布 新闻简报


文件
下载
选项
规格
应用
附件
用户手册
演示
常问问题


9102 Handheld Spectrum Analyzer

规格 (用英语)

Specifications apply for 9102B series devices with serial number 0604001 and higher without the 9151 Frequency Extension 7.5 GHz.

General data

Display (TFT)

Size

6.5''

Brightness

300 cd

Resolution

640 x 480, 256 colours

Measurement result points

2 x 501

Power supply

DC voltage, external

11 to 15 V / max. 28 W

Changeable Internal battery

Li-Ion

Operating time, battery fully charged, full brightness, TG on

2.0 h min.

Memory

Type

Flash Disk

Capacity (set-ups and traces)

257

Dimensions (W x H x D)

355 x 190 x 91 [mm]

Weight

With battery and Tracking Generator

3.2 kg (7 lbs)

Power supply only

0.32 kg (0.7 lbs)

Environmental conditions (unless otherwise specified)

MIL-PRF28800F class 2

Operating temperature

0 to +45 °C

Rel. humidity (non-condensing)

80%

Storage temperature

-10 to + 50 °C

Connectors

RF in

Connector type N (female), impedance 50 ohm

Serial interface

For software updates and remote control
Speed 57.6 kbit/s

LAN (TCP/IP)

For software updates and remote control
Speed 10 Mbit/s

Standard deliveries

9102 Handheld Spectrum Analyzer incl. power supply (90 to 240 V/50 to 60 Hz), crossover Ethernet communication cable, 9100 Data Exchange Software (1 license, user's guide on CD) and getting started manual

Frequency

Frequency range

Measurement range

100 kHz to 4 GHz

Resolution

1 kHz

Sweep time

Span > 10 kHz

1 ms to 250 s

Span = 0 Hz

1 ms to 250 s

Resolution bandwidth (RBW)

RBW (-3 dB) range 100 Hz to 1 MHz (RBW selection manual or automatic)

Video bandwidth (VBW)

VBW range (-3 dB) 10 Hz to 1 MHz (VBW selection manual or automatic)

SSB noise

< -80 dBc/Hz (f = 2 GHz, Δf = 100 kHz, RBW = 10 kHz, VBW = 1 kHz)

Amplitude

Measurement range

Averaged noise floor to 20 dBm

Display units

dBm, dBµV, dBmV, dBV, dB

Displayed average noise level (DANL) (RBW = 100 Hz, attenuation = 0 dB)

10 to 1000 MHz

< -127 dBm,
typ.-130 dBm

1000 to 4000 MHz

< -130 dBm,
typ.-135 dBm

Input attenuation

Setting range

0(10) to 50 dB

Attenuation steps

10 dB

Dynamic range

Range

> 70 dB

Max. measurable input level (attenuation = 40 dB)

20 dBm

Min. measurable input level

-130 dBm

Level accuracy

10 to 3600 MHz

±1 dB

RF input match (1 to 4000 MHz, input attenuation = 10 dB)

VSWR

< 1.6, typ. < 1.5

Return loss

< -12 dB

Spurious response

Image rejection (f = 1 GHz)

> 80 dB

LO breakthrough (attenuation = 10 dB)

< -77 dBm

Spurious level (attenuation = 0 dB)

< -90 dBm

Intermodulation-free range
(input level -30 dBm, f1 = 990 MHz, f2 = 992 MHz)

> 63 dB

Functions

Detector & sweep

Detector types

pos./neg. peak, pos. peak, neg. peak, sample

Sweep processing

actual, average, max. hold, min. hold

Trace

Max. displayed traces

2

Trace points

2 x 501
(Two independent traces are available, min. hold, max. hold at the same time)

Trace functions

A+B ? A, A-B ? A,
trace offset, copy a>b, copy b>a

Marker

Max. markers

6

Delta markers

5

Marker functions

max. peak, next peak

Transfer functions

M ? centre frequency, M ? ref. level, M ? f step

Limit check

Limit functions

upper, lower, upper and lower

Power measurement

Measurement functions

Channel Power, ACPR, OBW

Default systems

GSM, WCDMA, DECT, WLAN

Demodulation

AM/FM

on marker/permanent/on multi marker

9102 Handheld Spectrum Analyzer with 9151 Frequency Extension 7.5 GHz

Specifications

Frequency range

Measurement range

100 kHz to 7.5 GHz

SSB noise

< –80 dBc/Hz (f = 5.7 GHz, ?f = 100 kHz, RBW = 10 kHz, VBW = 1 kHz)

Displayed average noise level (DANL) (RBW = 100 Hz, attenuation = 0 dB)

10 MHz to 4 GHz

< –119 dBm, typ. –121 dBm

4 GHz to 7 GHz

< –120 dBm, typ. –123 dBm

7 to 7.5 GHz

< –113 dBm

Dynamic range

Range (5.000 GHz / 5.001 GHz)

> 70 dB

Max. measurable input level
(attenuation = 40 dB)

20 dBm

Min. measurable input level (<4 GHz)

–119 dBm

Min. measurable input level (4 GHz to 7 GHz)

–120 dBm

Min. measurable input level (7 GHz to 7.5 GHz)
(attenuation = 0 dB)

–112dBm

RF input match (input attenuation = 10 dB)

VSWR (100 MHz to 4 GHz)

< 1.6

VSWR (4 GHz to 6 GHz)

< 2.0

VSWR (6 GHz to 7.5 GHz)

< 2.3

Return loss (100 MHz to 4 GHz)

< –15 dB

Return loss (4 GHz to 6 GHz)

< –9 dB

Return loss (6 GHz to 7.5 GHz)

< –7 dB

Spurious response

Image rejection (f = 6.7 GHz) )

> 60 dB

Spurious level (100 kHz to 4 GHz)

< –90 dBm

Spurious level (4 GHz to 7.5 GHz)
(attenuation = 0 dB)

< –83 dBm

LO leakage (7.7 GHz)
(attenuation = 10 dB)

< –57 dBm


> 更多
关键词:
2008年10月7日
德国威尔泰克为中小规模手机维修店提供成本可以接受的测试仪器 > 更多信息
September 3, 2008
New features for Lector and Scriptor – free update! > 更多信息
2008年4月3日
新推出的天线耦合板方便TETRA无线设备测试 > 更多信息
2004年11月23日
威尔泰克推出新型、可扩展手持式频谱分析仪 > 更多信息
时事通讯
要求报价
保持联络
产品搜索引擎
术语汇编 (用英语)
资料打印
Top


版权保护 保密规则 法律声明