General data

Serial interface

D-Sub 25, female
4800, 9600, 19200, 38400 Baud

Printer interface

D-Sub 25, female

Voltage range

100 to 250 VAC

Voltage frequency

50 to 60 Hz

Power consumption

15 Watts

Size

250 x 110 x 95 mm

Weight

1.5 kg

Standard delivery Willtek 4100 Series

Getting started manual

User's guide on CD

Test SIM

Power supply

Calibration protocol

Basic RF data

Input/output impedance

50 O

VSWR

< 1.3

RF input/output

TNC-type, female

External ref. input

BNC-type, female
5/10/13 MHz

RF Signal Generator

Frequency range

GSM 900, E-GSM 900, GSM-R

935 to 960 MHz (Channel 1 to 124)
925 to 935 MHz (Channel 975 to 1023, 0)
921 to 925 MHz (Channel 955 to 974)

GSM 1800

1805 to 1880 MHz (Channel 512 to 885)

GSM 1900

1930 to 1990 MHz (Channel 512 to 810)

Frequency error

< 1 ppm

Output power level range
(GSM 900/E-GSM)
(GSM 1800/1900, dual band)


–45 to –110 dBm
–50 to –110 dBm

Output power level accuracy

< 1.5 dB
< 1.0 dB (S-version)

TX Measurement RF power measurement (burst)

Frequency range

GSM 900, E-GSM 900, GSM-R

890 to 915 MHz (Channel 1 to 124)
880 to 890 MHz (Channel 975 to 1023, 0)
876 to 880 MHz (Channel 955 to 974)

GSM 1800

1710 to 1785 MHz (Channel 512 to 885)

GSM 1900

1850 to 1910 MHz (Channel 512 to 810)

Frequency error

Measurement range

±5 kHz off carrier

Measurement accuracy
GSM 900
GSM 1800/1900


< 25 Hz
< 50 Hz

Power level measurement

Input power level range

–10 to +45 dBm

Input power level accuracy

< 1.5 dB (–10 to +39 dBm)

Power/time template

Dynamic range

> 40 dB

Phase error

Measurement range

1.5° to 20° rms

Measurement accuracy

GSM 900 < 1.5° rms
GSM 1800/1900 < 2.0° rms

Signalling capabilities

Location update

Mobile-originated/terminated call

Intracell handover

Cross-band handover

Call clearing by MS/Tester

Closed/open loop procedure


> more
Keyword:
February 16, 2011
New firmware for 2305 Stabilock adds Autorun capability for base station testing, new option for BS remote control > more
February 2, 2011
Aeroflex Introduces New Options for 2201 ProLock Phone Tester to Increase WCDMA Test Speed, Add Handover to GSM and HSDPA Test > more
April 20, 2010
New TETRA tester supports service of base stations and radio terminals > more
4192 GSM Phone Checker Package > more
4916 Antenna Coupler - Next-Generation Antenna Coupler for All Mobile Phones > more
Newsletter
Request a quote
Glossary
Print
Top


Copyright Privacy Policy Legal Information