Home Contact Us Sitemap Home Sales Partner World
Products Solutions Technologies Services Company Press News


Literature
Downloads
Options
Specifications
Applications
Accessories
Manuals
Demonstration
FAQs


9101 Handheld Spectrum Analyzer

Specifications

General data

Display (TFT)

Size

6.5''

Brightness

300 cd

Resolution

640 x 480, 256 Colours

Measurement result points

2 x 501
(Two independent traces are available,
min. hold, max. hold at the same time)

Power supply

DC voltage, external

11 to 15 V / max. 28 W

Changeable Internal battery

Li-Ion

Operating time (battery fully charged, full brightness)

min. 2.1 h

Memory

Type

Flash Disk

Capacity (set-ups and traces)

257

Dimensions (W x H x D)

355 x 190 x 85 [mm]

Weight

With battery

3.0 kg (6.6 lbs)

Power supply only

0.32 kg (0.7 lbs)

Environmental conditions (unless otherwise specified)

MIL-PRF28800F class 2

Operating temperature

0 to +45°C

Rel. humidity (non-condensing)

80%

Storage temperature

–10 to + 50°C

Connectors

RF in

Connector type N (female), impedance 50 ohm

Serial interface

For software updates and remote control
Speed 57.6 kbit/s

LAN (TCP/IP)

For software updates and remote control
Speed 10 Mbit/s

Standard deliveries

9101 Handheld Spectrum Analyzer incl. 9100 Data Exchange Software, AC power supply (90 to 240 V/50 to 60 Hz), Cross-link Ethernet cable, user's guide on CD and getting started manual

Frequency

Frequency range

Measurement range

100 kHz to 4 GHz

Frequency accuracy

2 ppm

Resolution

1 kHz

Sweep time

Span > 100 kHz

1 ms to 250 s

Span = 0 Hz

1 ms to 250 s

Resolution bandwidth (RBW)

RBW (–3 dB) range 100 Hz to 1 MHz (RBW selection manual or automatic)

Video bandwidth (VBW)

VBW range (–3 dB) 10 Hz to 1 MHz (VBW selection manual or automatic)

SSB noise

< –83 dBc/Hz (f = 2 GHz, Δf = 100 kHz, RBW = 10 kHz, VBW = 1 kHz)

Amplitude

Measurement range

Averaged noise floor to 20 dBm

Display units

dBm, dBµV, dBmV, dBV, dB, V, mV, µV, mW, µW

Displayed average noise level (DANL) (RBW = 100 Hz, attenuation = 0 dB)

10 to 1000 MHz

< –127 dBm,
typ.–130 dBm

1000 to 4000 MHz

< –130 dBm,
typ.–125 dBm

Input attenuation

Setting range

(0) 10 to 50 dB

Attenuation steps

10 dB

Dynamic range

Range

> 65 dB

Max. measurable input level (attenuation = 50 dB)

20 dBm

Min. measurable input level

–130 dBm

Level accuracy

10 to 3600 MHz

±1 dB

VSWR RF input

10 to 4000 MHz, input attenuation = 10dB

< 1.6

Spurious response

Image rejection (f = 1 GHz)

> 80 dB

LO breakthrough (attenuation = 10 dB)

< –72 dBm

Spurious level (attenuation = 0 dB)

< –90 dBm

Intermodulation-free range
(input level –30 dBm, f1 = 990 MHz, f2 = 992 MHz)

> 63 dB

Frequency counter

Resolution

1 Hz, 10 Hz, 100 Hz

Min. required input level

-90 dBm

Functions

Detector & sweep

Detector types

pos./neg. peak, pos. peak, neg. peak, sample, RMS (optional)

Sweep processing

actual, average, max. hold, min. hold

Trace

Max. displayed traces

2

Trace points

2 x 501
(Two independent traces are available, min. hold, max. hold at the same time)

Trace functions

A+B → A, A–B → A,
copy a>b, copy b>a

Marker

Max. markers

6

Delta markers

5

Marker functions

max. peak, next peak

Transfer functions

M → centre frequency, M → ref. level, M → f step

Limit check

Limit functions

upper, lower, upper and lower

Power measurement

Measurement functions

Channel Power, ACPR, OBW

Default systems

GSM, WCDMA, DECT, WLAN

Demodulation

AM/FM

on marker/permanent/on multi marker


> more
Keyword:
March 10, 2010
Low-cost solution meets growing demand for WiFi test equipment > more
February 10, 2010
Willtek introduces extra-large RF shield > more
January 19, 2010
Willtek’s service test system for 3G mobile phones now self-contained > more
Download the software you need > more
Newsletter
Request a quote
Stay in touch
Product Finder
Glossary
Print
Top


Copyright Privacy Policy Legal Information