General data
Serial interface
D-Sub 9, female 4800, 9600, 19200, 38400 Baud
Printer interface
D-Sub 25, female
Mains voltage range
100 to 250 VAC
Mains voltage frequency
50 to 60 Hz
Power consumption
17 Watts
Storage temperature
–30°C to +50°C
Operating temperature
+15°C to –35°C
Size
310 x 170 x 165 mm
Weight
2.4 kg
Basic RF data
Input/output impedance
50 Ω
VSWR
< 1.9
RF input/output
N-type, female
Internal reference frequency
13 MHz
Aging
10–6 /year
External ref. input
BNC-type, female 5/10/13 MHz
RF Generator
Frequency range
GSM 900, E-GSM
935 to 960 MHz (Channel 1 to 124) 925 to 935 MHz (Channel 975 to 1023, 0)
GSM 1800
1805 to 1880 MHz (Channel 512 to 885)
GSM 1900
1930 to 1990 MHz (Channel 512 to 810)
GSM 850 (optional)
869 to 894 MHz (Channel 128 to 251)
Reference frequency accuracy (without external reference oscillator)
< 10–6
Output level range
GSM 850/900 GSM 1800/1900
–24 to –103 dBm –30 to –103 dBm
Resolution
0.1 dB
Output level accuracy
For levels –96 to –24 dBm
< 1.0 dB
Operating temperature range
+20°C to +30°C
RF analyzer
890 to 915 MHz (Channel 1 to 124) 880 to 890 MHz (Channel 975 to 1023, 0)
1710 to 1785 MHz (Channel 512 to 885)
1850 to 1910 MHz (Channel 512 to 810)
GSM 850 (option)
824 to 849 MHz (Channel 128 to 251)
Frequency error measurement
Measurement range
±10 kHz off carrier
Usable range
±45 kHz
Measurement accuracy GSM 850/900 GSM 1800/1900
< 15 Hz < 25 Hz
Power level measurement
Burst mode
–54 to +25 dBm
CW mode
–54 to +19 dBm
Measurement accuracy
< 1.1 dB (-17 to +25 dBm)< 1.5 dB (-54 to -17 dBm)
Dynamic range
Power/time template
> 40 dB
I/Q alignment mask
> 60 dB
Phase error measurement
1.5° to 20° rms
< 0.8° rms < 1.4° rms
Timing advance accuracy
1/4 Bit