General data

Serial interface

D-Sub 9, female
4800, 9600, 19200, 38400 Baud

Printer interface

D-Sub 25, female

Mains voltage range

100 to 250 VAC

Mains voltage frequency

50 to 60 Hz

Power consumption

17 Watts

Storage temperature

–30°C to +50°C

Operating temperature

+15°C to –35°C

Size

310 x 170 x 165 mm

Weight

2.4 kg

Basic RF data

Input/output impedance

50 Ω

VSWR

< 1.9

RF input/output

N-type, female

Internal reference frequency

13 MHz

Aging

10–6 /year

External ref. input

BNC-type, female
5/10/13 MHz

RF Generator

Frequency range

GSM 900, E-GSM

935 to 960 MHz (Channel 1 to 124)
925 to 935 MHz (Channel 975 to 1023, 0)

GSM 1800

1805 to 1880 MHz (Channel 512 to 885)

GSM 1900

1930 to 1990 MHz (Channel 512 to 810)

GSM 850 (optional)

869 to 894 MHz (Channel 128 to 251)

Reference frequency accuracy
(without external reference oscillator)

< 10–6

 

Output level range

GSM 850/900
GSM 1800/1900

–24 to –103 dBm
–30 to –103 dBm

Resolution

0.1 dB

Output level accuracy

For levels –96 to –24 dBm

< 1.0 dB

Operating temperature range

+20°C to +30°C

RF analyzer

Frequency range

GSM 900, E-GSM

890 to 915 MHz (Channel 1 to 124)
880 to 890 MHz (Channel 975 to 1023, 0)

GSM 1800

1710 to 1785 MHz (Channel 512 to 885)

GSM 1900

1850 to 1910 MHz (Channel 512 to 810)

GSM 850 (option)

824 to 849 MHz (Channel 128 to 251)

Frequency error measurement

Measurement range

±10 kHz off carrier

Usable range

±45 kHz

Measurement accuracy
GSM 850/900
GSM 1800/1900


< 15 Hz
< 25 Hz

Power level measurement

Measurement range

Burst mode

–54 to +25 dBm

CW mode

–54 to +19 dBm

Measurement accuracy

< 1.1 dB (-17 to +25 dBm)
< 1.5 dB (-54 to -17 dBm)

Dynamic range

Power/time template

> 40 dB

I/Q alignment mask

> 60 dB

Phase error measurement

Measurement range

1.5° to 20° rms

Measurement accuracy
GSM 850/900
GSM 1800/1900


< 0.8° rms
< 1.4° rms

Timing advance accuracy

1/4 Bit


> mehr
Suchbegriff:
16. Februar 2011
Neue Firmware für 2305 Stabilock unterstützt Autorun für Basisstationstest; neue Option für BS-Steuerung > mehr
2. Februar 2011
Aeroflex bietet neue Optionen für den 2201 ProLock für schnellere WCDMA-Tests und Handover-Tests zu GSM und HSDPA > mehr
20. April 2010
Neuer TETRA-Tester unterstützt Wartung und Service an Basisstationen und Endgeräten > mehr
12. April 2005
Willtek Communications bringt den 4208 Off-Air Mobile Tester für die Automobilindustrie zur kabellosen Überprüfung der installierten Kommunikationseinrichtungen auf den Markt > mehr
Newsletter
Angebotsanfrage
Glossar (englisch)
Drucken
Top


Impressum Datenschutz Rechtliche Hinweise